With the aid of professional and perfect test support, we ensure the stability and excellent quality of the roots blower flow rate, portable vacuum pump, management system so that make us occupy the leading position in the industry. You can have a variety choices and the value of all types are same reliable. We uphold a rigorous scientific attitude, pragmatic work style, and honest business philosophy to create a better tomorrow with our customers!
Products name: DN125 (5 inch) roots blower
Brand:RH
Model:RH12542
Place of orign:Nantong China
Drive :direct coupling / V-belt transmission
color: blue or silver
Motor brand: Jianghuai , Wannan,Teco
Power:22kw /18.5kw/37kw
Motor protection class: IP55, Variable frequency motor available
Weight:750kg approx.
Flow capacity:15-25m3/min
Pressure:9.8-98kpa
Rotation speed:1200rp-2050rpm
Rated Voltage:380V,50HZ,3P;440V/60HZ/3P
lubrication: oil, grease
Noise: less than 81dB(A) 1 meter distance from roots blower
cooling water connection size:DN15,G1/2 male thread for inlet pipe, female thread for outlet pipe


Q:What is the advantage of water cooling roots blower?
A:water cooling roots blower are advanced designed for tackling harsh working conditions such as high pressure which may higher than 68kpa, thus we suggest using water cooling type roots blower. The cooling water give the blower better cooling effect to reduce blower temprature. Thus the blower can oprerate for long time at a higher pressure case.
Where is the most common cooling water blower Application?
A: Water cooling roots blower are widely used in sewage treatment plant, wastewater treatment plant
for water aeration or v-type filter backwash.The water type is suitable when resistance is higher than 68.6kpa.
water cooling can reduce the blower body temperature and have a better performance.
Q:What is the precautions when operation the cooling water roots blower?
A:The water inlet is located at middle level and outlet is at the top. The drain is at the bottom of the blower which should be closed when operation. When the room temperature is below 0 degree or below this frozen temperature, the cooling water should be drained in case frozen
| RH12542 | 980 | 9.8 | 1000 | 13.1 | 4.1 | Y2-132M2-6 | 5.5 | 624 |
| 19.6 | 2000 | 12.4 | 6.3 | Y2-160M-6 | 7.5 | 658 | ||
| 29.4 | 3000 | 11.8 | 8.5 | Y2-160L-6 | 11 | 685 | ||
| 39.2 | 4000 | 11.2 | 10.7 | Y2-180L-6 | 15 | 735 | ||
| 49 | 5000 | 10.6 | 12.9 | Y2-180L-6 | 15 | 735 | ||
| 58.8 | 6000 | 10.2 | 15.1 | Y2-200L1-6 | 18.5 | 760 | ||
| 68.6 | 7000 | 9.8 | 17.2 | Y2-200L1-6 | 18.5 | 760 | ||
| 78.4 | 8000 | 9.3 | 19.5 | Y2-200L2-6 | 22 | 790 | ||
| 88.2 | 9000 | 8.4 | 21.7 | Y2-225M-6 | 30 | 832 | ||
| 98 | 10000 | 7.9 | 23.9 | Y2-225M-6 | 30 | 832 | ||
| 1100 | 9.8 | 1000 | 15.1 | 4.6 | Y2-132S-4 | 5.5 | 607 | |
| 19.6 | 2000 | 14.3 | 7.1 | Y2-160M-4 | 11 | 664 | ||
| 29.4 | 3000 | 13.6 | 9.5 | Y2-160M-4 | 11 | 664 | ||
| 39.2 | 4000 | 13.2 | 12.0 | Y2-160L-4 | 15 | 685 | ||
| 49 | 5000 | 12.7 | 14.6 | Y2-180M-4 | 18.5 | 720 | ||
| 58.8 | 6000 | 12.3 | 17.1 | Y2-180M-4 | 18.5 | 720 | ||
| 68.6 | 7000 | 11.9 | 19.7 | Y2-180L-4 | 22 | 740 | ||
| 78.4 | 8000 | 11.2 | 22.3 | Y2-200L-4 | 30 | 810 | ||
| 1200 | 9.8 | 1000 | 16.4 | 5.0 | Y2-132M-4 | 7.5 | 621 | |
| 19.6 | 2000 | 15.7 | 7.7 | Y2-160M-4 | 11 | 664 | ||
| 29.4 | 3000 | 15.4 | 10.4 | Y2-160L-4 | 15 | 685 | ||
| 39.2 | 4000 | 14.7 | 13.1 | Y2-160L-4 | 15 | 685 | ||
| 49 | 5000 | 14.3 | 15.8 | Y2-180M-4 | 18.5 | 720 | ||
| 58.8 | 6000 | 13.8 | 18.5 | Y2-180L-4 | 22 | 740 | ||
| 68.6 | 7000 | 13.4 | 21.3 | Y2-200L-4 | 30 | 810 | ||
| 78.4 | 8000 | 12.7 | 24.1 | Y2-200L-4 | 30 | 810 | ||
| 1310 | 9.8 | 1000 | 18.1 | 5.5 | Y2-132M-4 | 7.5 | 621 | |
| 19.6 | 2000 | 17.4 | 8.4 | Y2-160M-4 | 11 | 664 | ||
| 29.4 | 3000 | 16.7 | 11.4 | Y2-160L-4 | 15 | 685 | ||
| 39.2 | 4000 | 16.2 | 14.4 | Y2-180M-4 | 18.5 | 720 | ||
| 49 | 5000 | 15.6 | 17.4 | Y2-180M-4 | 18.5 | 720 | ||
| 58.8 | 6000 | 15.2 | 20.4 | Y2-180L-4 | 22 | 740 | ||
| 68.6 | 7000 | 14.9 | 23.5 | Y2-200L-4 | 30 | 810 | ||
| 78.4 | 8000 | 14.3 | 26.6 | Y2-200L-4 | 30 | 810 | ||
| Model | Speed(n) | △P | inlet Capacity(Q) | shaft power | motor | weight | ||
| r/min | kPa | mmH2O | m3/min | kW | model | kW | kg | |
| RH12542 | 1450 | 9.8 | 1000 | 20.1 | 6.1 | Y2-132M-4 | 7.5 | 621 |
| 19.6 | 2000 | 19.4 | 9.5 | Y2-160M-4 | 11 | 664 | ||
| 29.4 | 3000 | 18.9 | 12.8 | Y2-160L-4 | 15 | 685 | ||
| 39.2 | 4000 | 18.3 | 16.2 | Y2-180M-4 | 18.5 | 720 | ||
| 49 | 5000 | 17.7 | 19.5 | Y2-180L-4 | 22 | 740 | ||
| 58.8 | 6000 | 17.4 | 22.9 | Y2-200L-4 | 30 | 810 | ||
| 68.6 | 7000 | 17.1 | 26.3 | Y2-200L-4 | 30 | 810 | ||
| 78.4 | 8000 | 16.7 | 29.7 | Y2-225S-4 | 37 | 824 | ||
| 88.2 | 9000 | 15.9 | 33.1 | Y2-225S-4 | 37 | 824 | ||
| 98 | 10000 | 15.0 | 36.6 | Y2-225M-4 | 45 | 860 | ||
| 1600 | 9.8 | 1000 | 22.3 | 6.9 | Y2-160M-4 | 11 | 664 | |
| 19.6 | 2000 | 21.5 | 10.8 | Y2-160L-4 | 15 | 685 | ||
| 29.4 | 3000 | 20.8 | 14.7 | Y2-180M-4 | 18.5 | 720 | ||
| 39.2 | 4000 | 20.4 | 18.6 | Y2-180L-4 | 22 | 740 | ||
| 49 | 5000 | 19.9 | 22.5 | Y2-200L-4 | 30 | 810 | ||
| 58.8 | 6000 | 19.2 | 26.5 | Y2-200L-4 | 30 | 810 | ||
| 68.6 | 7000 | 19.3 | 30.3 | Y2-225S-4 | 37 | 824 | ||
We are also a unified big family, everyone stick to the company value 'unification, dedication, tolerance' for Elestar Brand PS-126 Small Water Pump for Garden Use. We adopt advanced management, implement lean production, and strictly control quality to ensure that the products produced by our company are of high quality and low price. At the same time, the factory has always been adhering to the user's needs as the core, focusing on product market development, providing enterprises with high-quality, attentive and complete after-sales service, winning the trust and praise of many enterprises. In terms of development, our company will adhere to the development goal of continuous research and development, adapt to the change of environment, carry out technology research and development and continuously develop the market.